TG/DTA – EXSTAR 6000Series

NEW EXSTAR7000 DSC Series

  • TOP Of the RANGE DSC
  • Wide Temperature Range (-170 to 1500°C)
  • Unsurpassed sensitivity : run samples of less than 0.2mg
  • Scanning rates: 0.01 to 100 degrees per minute
  • Smallest sample pans for best heat transfer
  • Auto sampler
  • Cooling systems for all needs

For More information on the product, click here

Also: EXSTAR6000 DSC Series

  • High Performance Heat Flux DSC
  • Wide Temperature Range (-170 to 1500°C)
  • Excellent sensitivity
  • Auto sampler
  • Cooling systems for all needs

The SII NanoTechnology EXSTAR DSC series shows the greatest flexibility. A range of cooling devices, all of which being compatible on the same base unit, are available. Each one will allow variyng degrees of flexibility in the-170 to 1500°C temperature range. The user will be able to exchange or upgrade to any of these sensors at any time.

DSC 6100

The DSC 6100 is designed to have super high sensitivity with flat and reproducible baselines to meet high sensitivity application requirements. The ideal instrument for food, biotechnology research works and low density solution analysis applications.

DSC 6200

The DSC 6200 offer several inherent benefits due to its unique design. The performance of high sensitivity and excellent baseline stability are typical for DSC 6200. The exclusive oval structure sensor creates the shortest heat pass, which gives the best time constant. The instrument fulfils all the needs for Polymer food and pharmaceutical applications in R&D, as well as in quality control.

DSC6300

Designed with the high temperature, high sensitivity sensor and the unique gas exchange system it guarantees the desired atmosphere up to 1500°C. It is the best equipment to analyse metal and ceramic samples.

Auto Sampler

The optional auto sampler for DSC 6200 provides high throughput to your laboratory. To achieve the most accurate and reproducible results, the reliable 50 position robotic auto sampler uses the patented mechanical fingers to position the containers with the highest accuracy. User friendly software and easy position alignment together with the great flexibility guarantee the effective use of the fully automated DSC 6200 system.

Various Cooling Systems

Different cooling system allow measurements in the temperature range from -170 to 725°C. Depending on the customer application the cooling system can be chosen.

  • Liquid Nitrogen Cooling Accessory
  • Fully automated cooling and heating from -150 to 725°C
  • Electrical Cooling system
  • For controlled cooling and heating from-75 to 380°C without following costs
  • Forced Air Cooling
  • The cost effective way to cool quickly down to ambient
  • Cooling Can
  • Low cost, for rapid and quench cooling down to -170°C

For further information and prices, please click here. Or Click below to be redirected to the SIINT site: